Whole-house air filtration and ERV/HRV sizing
Enter your home's size, heating system, climate and main concern. The tool works out the house volume, the ventilation rate in CFM, and which equipment fits.
Recommended whole-house architecture
Media cabinet at MERV 13 or higher on the return, with a bypass HEPA unit as the step up, plus an ERV at 90 CFM
- House volume
- 16,000 cu ft
- Required ventilation
- 90 CFM
- Unit capacity to buy
- about 130 CFM
- Outdoor air changes
- 0.3 ACH
Primary for your concern
Media filter cabinet
4- to 5-inch deep media, MERV 13 to 16
Smoke particles are mostly under 1 micron. EPA and ASHRAE point to MERV 13 or higher for wildfire smoke; a deep media cabinet gets there with less pressure drop than a 1-inch filter.
- Installed
- $600 to $1,500
- Equipment only
- $150 to $400
- Benchmark models
- Aprilaire 2210 / 2410, Honeywell Home F100
Supporting
Bypass HEPA unit
True HEPA (99.97% at 0.3 micron) on a bypass loop off the return duct
Worth adding if smoke seasons are long or the blower cannot handle MERV 16 media. It filters a side-stream with its own fan, so it does not load the main blower.
- Installed
- $1,500 to $4,000
- Equipment only
- $900 to $2,000
- Benchmark models
- Bypass HEPA units sized 200 to 300 CFM
Supporting
ERV (energy recovery ventilator)
90 CFM continuous; choose a unit rated about 130 CFM
An ERV handles both humid summers and cold winters, which suits mixed climates. It can tie into the existing return and supply ducts.
- Installed
- $2,000 to $5,000
- Equipment only
- $800 to $2,500
- Benchmark models
- Panasonic Intelli-Balance, Broan AI Series
Cost summary
| Scope | Range |
|---|---|
| Installed, equipment plus duct integration | $2,600 to $6,500 |
| Equipment only, for a do-it-yourself benchmark | $950 to $2,900 |
Totals leave out the optional bypass HEPA unit and portable room cleaners.
Design note
Have the installer measure total external static pressure before and after a filter upgrade. A high-MERV filter in a 1-inch slot can starve the blower.
Design note
During a smoke event, lower or pause mechanical ventilation and rely on recirculating filtration. An ERV or HRV pulls smoky outdoor air through its own filter, which is rarely better than MERV 13.
Filtration and ventilation do different jobs
Filtration cleans the air already in the house by passing it through a filter again and again. It removes particles: smoke, dust, pollen. Ventilation swaps indoor air for outdoor air. It dilutes what filters cannot catch, such as CO₂, odours and moisture from cooking and breathing. Most homes that want better air need some of each, and the tool sizes both.
Media cabinet or bypass HEPA
A media cabinet replaces the 1-inch filter slot with a housing for a 4- or 5-inch deep pleated filter. Deeper pleats mean more filter area, so a MERV 13 media filter can have less resistance than a 1-inch MERV 13 and last six months to a year. It is the first upgrade for a forced-air home.
A bypass HEPA unit is a separate box ducted to the return. Its own fan pulls a few hundred CFM off the return, through a HEPA filter, and puts it back. Because it does not sit in the main airstream it does not load the furnace blower. It costs more, and it only cleans the house while the central fan circulates air.
MERV ratings in brief
| Rating | Captures (ASHRAE 52.2) | Typical use |
|---|---|---|
| MERV 8 | At least 70% of 3 to 10 micron particles | Basic dust and lint; protects equipment |
| MERV 11 | At least 65% of 1 to 3 micron particles | Pollen, dust, pet dander |
| MERV 13 | At least 50% of 0.3 to 1 micron particles | Smoke; EPA's recommended floor for wildfire events |
| MERV 16 | At least 95% of 0.3 to 1 micron particles | Highest non-HEPA media; check blower capacity |
| HEPA | 99.97% of 0.3 micron particles | Bypass units and portable room cleaners |
How the CFM figure is calculated
The tool uses the ASHRAE 62.2 whole-dwelling rate: 0.03 × floor area + 7.5 × (bedrooms + 1). It then suggests a unit rated about 25% higher, so the ventilator can meet the rate on a lower, quieter speed and has a boost setting in reserve. Ceiling height does not change the required CFM, but it changes the volume and so the air changes per hour.
The formula gives the rate for mechanical ventilation with no credit for air leakage. An energy auditor with a blower door test can apply the standard's infiltration credit, which lowers the figure for leaky houses.
Installed cost and equipment-only prices
| Equipment | Installed | Equipment only |
|---|---|---|
| Media filter cabinet, MERV 11 to 16 | $600 to $1,500 | $150 to $400 |
| Bypass HEPA unit | $1,500 to $4,000 | $900 to $2,000 |
| ERV or HRV, existing ducts | $2,000 to $5,000 | $800 to $2,500 |
| ERV or HRV, dedicated ducts | $3,500 to $8,000 | $800 to $2,500 |
| Whole-house dehumidifier | $2,000 to $3,500 | $1,200 to $2,000 |
The gap between the two columns is sheet metal, duct runs, wiring, controls and commissioning. A media cabinet is a realistic do-it-yourself job for someone comfortable cutting sheet metal. An ERV or HRV needs balanced airflows measured at start-up, which is the part worth paying for.
Common questions
What MERV rating do I need for wildfire smoke?
EPA and ASHRAE guidance points to MERV 13 or higher for smoke, because most smoke particles are smaller than 1 micron. Use the highest rating your system can handle without restricting airflow, and have static pressure checked if you move up from a low-MERV filter.
What is the difference between an ERV and an HRV?
Both bring in outdoor air and exhaust indoor air through a core that recovers heat. An HRV transfers heat only. An ERV also transfers some moisture, so it brings in less humidity in summer and loses less in winter. ERVs suit humid, mixed and dry climates; HRVs are the traditional choice in cold climates where winter moisture needs to leave the house.
How many CFM of ventilation does a house need?
ASHRAE 62.2 sets the whole-dwelling rate at 0.03 CFM per square foot of floor area plus 7.5 CFM per occupant, counted as bedrooms plus one. A 2,000 sq ft, three-bedroom home needs 90 CFM running continuously.
Is a bypass HEPA unit better than a MERV 16 filter?
They solve the problem differently. A MERV 16 media filter treats all the air the blower moves but adds resistance. A bypass HEPA unit captures 99.97% of 0.3 micron particles but only filters a side-stream, typically 200 to 300 CFM, using its own fan. HEPA is the step up when the main blower cannot handle dense media.
Can I add whole-house filtration without ducts?
Not in the usual sense. Whole-house filters sit in the return duct of a forced-air system. In a ductless or radiator-heated home, use portable HEPA cleaners sized by CADR for each room, and a ducted ERV or HRV with a MERV 13 supply filter for fresh air.
Does an air filter lower CO₂ or humidity?
No. Particle filters remove particles. CO₂ falls only when outdoor air replaces indoor air, which is what an ERV or HRV does. Humidity is controlled by air conditioning or a dehumidifier.