Skip to content
AirVitalize

How we work, and who pays for it

AirVitalize is an independent US reference for home air quality costs and HVAC sizing. This page explains where the numbers come from, what we will not claim, and how the site earns money.

What this site is

We publish calculators and guides for five kinds of home air work: radon mitigation, mold remediation, whole-house filtration, mechanical ventilation, and heat pumps. The aim is narrow. Before a homeowner speaks to a contractor, they should know what the job consists of, roughly what each part costs, and which questions separate a complete quote from a cheap one.

We are not contractors, and we do not inspect, test or install. We are not a medical source either. Nothing on this site diagnoses a health condition or says that a product will improve one.

Methodology

Cost ranges

Every dollar figure is a planning range for 2026 for a typical US single-family home. Each range has a low and a high, and each calculator adds the lows and the highs separately so the total shows the real spread. We round to the nearest $25 or $50 so the output does not look more exact than it is.

All ranges live in one data file, reviewed on a schedule and dated in the page footer. The current figures were last reviewed in 2026-11. The main anchors are:

  • Radon: active sub-slab depressurization at $800 to $2,500 depending on foundation, with one more suction point assumed for each 1,500 sq ft of footprint beyond 2,500.
  • Mold: $10 to $25 per sq ft for standard areas and $15 to $30 for attics, crawl spaces and HVAC, with a minimum job charge on small areas.
  • Ventilation: $2,000 to $5,000 installed for an ERV or HRV tied into existing ducts, more with dedicated ductwork.
  • Heat pumps: equipment at $1,100 to $2,000 per ton for central systems, with labor, ducts and electrical priced as separate lines.

Regional adjustment

The radon tool adjusts labor-heavy lines by a state multiplier between roughly 0.87 and 1.28. The multipliers are our own estimates of relative construction labor cost. Equipment that sells at national prices, such as a radon monitor, is not adjusted. A multiplier is a blunt tool: prices inside a state vary more than prices between states, and a rural job can cost more than a city job because of travel.

Sizing

Ventilation rates use the ASHRAE 62.2 whole-dwelling formula: 0.03 CFM per square foot of floor area plus 7.5 CFM per occupant, counting occupants as bedrooms plus one. We recommend a unit rated about 25% above that so it can run below top speed. Heat pump capacity uses a rule of thumb in BTU per square foot by climate, and every result says so and asks for an ACCA Manual J load calculation in its place.

What the estimates cannot know

A calculator cannot see your house. It does not know the soil under the slab, how far the pipe has to run, what is behind the wall, or how leaky the ducts are. Treat the output as a way to read quotes, not as a quote.

Data sources

  • US EPA, radon. The 4.0 pCi/L action level, the 2.0 to 4.0 pCi/L "consider fixing" band, post-mitigation testing guidance, and the EPA Map of Radon Zones. EPA states the map is for targeting resources and building codes, and should not be used to decide whether a home needs testing. We repeat that wherever we show zone data.
  • US EPA, mold. The guideline that areas under about 10 square feet can usually be cleaned by the occupant, the advice not to run a contaminated HVAC system, and the principle that the moisture source must be fixed.
  • US EPA, indoor air. Guidance on MERV 13 or higher filtration for wildfire smoke and on indoor relative humidity.
  • ASHRAE. Standard 62.2 for residential ventilation rates and Standard 52.2, which defines MERV ratings.
  • AHAM. The clean air delivery rate (CADR) method and the two-thirds sizing guideline for portable air cleaners.
  • ANSI/AARST. Radon mitigation standards of practice, and AARST's table of state credential requirements.
  • State agencies and statutes. Licensing and certification rules on each state page cite the administering agency and the law.
  • IRS, DOE and state energy offices. The end of the Section 25C credit on December 31, 2025, and the status of HEAR and HOMES rebates.

Rules and rebate programs change. If you find something out of date, we want to know.

Editorial independence

  • Cost ranges and recommendations are set from the sources above. No contractor network, manufacturer or retailer sees them before publication or can pay to change them.
  • Every calculator shows its full result without asking for an email address, a phone number or a ZIP code. Quote requests are offered only after the result, and only as an option.
  • We do not store contact details. When partner quote forms are live, the partner hosts the form on its own system and handles consent to be contacted.
  • We do not publish contractor listings or reviews we cannot verify, and we do not invent them.
  • We make no medical claims. Equipment is described by what it does to air, in units that can be measured.
  • Products named as benchmarks are examples of a category. Naming one is not a statement that it is the best choice for your home.

Affiliate and partner disclosure

AirVitalize is free to use and is funded by referral fees. There are two kinds.

  • Contractor quote networks. Below a calculator result we may link to a service that matches homeowners with local contractors: Angi for radon, mold and HVAC; Networx for mold and HVAC; Modernize for heat pumps, ducts and indoor air quality. If you submit a request through one of those links, the network may pay us.
  • Equipment retailers. Product comparison cards may link to Sylvane, SupplyHouse or Amazon. If you buy through one of those links, the retailer may pay us a commission.

In both cases you pay nothing extra. Paid links are marked where they appear and carry the rel="sponsored" attribute.

Current status: no paid links are active on this site yet. The sections under each calculator currently show a contractor checklist and product specifications with no outbound referral links. This page will be updated when that changes.